034B Wind Set
Reliable, Accurate Wind Measurements
Compatible with most Campbell Scientific dataloggers
weather applications supported water applications supported energy applications supported gas flux and turbulence applications supported infrastructure applications supported soil applications supported

Overview

The 034B, manufactured by Met One, combines a 3-cup anemometer and vane into a single integrated package to measure wind speed and direction. It is cabled for use with our dataloggers, and can provide measurements for a variety of applications.

Read More

Benefits and Features

  • Designed for continuous, long-term, unattended operation in adverse conditions
  • Constructed of lightweight aluminum

Technical Description

The 034B monitors wind speed using a three-cup anemometer that contains a sealed magnetic reed switch. Rotation of the cup wheel produces a pulse that is directly proportional to wind speed. The frequency of the pulse is measured by the datalogger pulse count channel, then converted to engineering units (mph, m/s, knots).

Wind direction is sensed with a potentiometer. With the precision excitation voltage from the datalogger applied to the potentiometer element, the output signal is an analog voltage that is directly proportional to the azimuth of the wind direction.

Images


Specifications

Applications General (Rain with light snow. Little or now riming or blowing sand. No salt spray.)
Sensor 3-cup anemometer and vane
Measurement Description Wind speed and direction
Operating Temperature Range -30° to +70°C
Weight 907 g (2.0 lb)

Wind Speed (Anemometer)

Range 0 to 75 m/s (0 to 167 mph)
Starting Threshold 0.4 m/s (0.9 mph)
Sensor Output Pulsed contact closure
Accuracy
  • 0.1 m/s (0.25 mph) at < 10.14 m/s (22.7 mph)
  • ±1.1% of true at > 10.14 m/s (22.7 mph)
Resolution (0.7998 m s–1) / (scan rate in seconds) or (1.789 mph) / (scan rate in seconds)
Anemometer Radius 10.7 cm (4.2 in.)
Anemometer Height 24.4 cm (9.6 in.)
Output Signal Contact closure (reed switch)

Wind Direction (Vane)

Mechanical Range 360°
Electrical Range 356° (4° open)
Accuracy ±4°
Damping Ratio 0.25
Resolution < 0.5°
Potentiometer Resistance 0 to 10 kΩ (open at crossover)
Threshold 0.4 m s–1 (0.9 mph)
Vane Length 33.5 cm (13.2 in.)

Compatibility

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Dataloggers

Product Compatible Note
CR1000 (retired)
CR1000X
CR300 (retired)
CR3000
CR310
CR350
CR6
CR800 (retired)
CR850 (retired)

Additional Compatibility Information

Mounting

The 034B can be attached to a Campbell Scientific crossarm using a 17953 Nu-Rail fitting or a CM220 Right Angle Mounting Bracket. Alternatively, the 034B can be attached to the top of our stainless-steel tripods via the CM216 Sensor Mounting Kit. The CM216 extends 4 inches above the mast of a CM106B, CM110, CM115, or CM120 tripod.

Data Logger Considerations

The 034B's anemometer uses one pulse count channel on the data logger. Its wind vane requires one single-ended channel and access to an excitation channel (the excitation channel can be shared with other high impedance sensors).

Programming

The 034B's anemometer is measured by the PulseCount Instruction in CRBasic, and by Instruction 3 (Pulse Count) in Edlog. The wind vane is measured by the BrHalf Instruction in CRBasic and by Instruction 4 (Excite-Delay-SE) in Edlog. The measurements are typically processed for output with the Wind Vector instruction (not present in the CR500 or CR9000).

Resources and Links

Product Brochures


FAQs for

Number of FAQs related to 034B: 15

Expand AllCollapse All

  1. No. A data logger is needed to measure and store data from the 034B-L.

  2. Wind vane tails are user-replaceable and are available for purchase as pn 13765Replacement Wind Vane Tail for 034B or 034A.

  3. They are completely interchangeable, and no changes are needed.

  4. For proper siting of the wind sensor, refer to the 034B-L manual. The 034B-L can be mounted using a 1.00 IPS pipe of any length.

  5. The sensor does not consume power to operate.

  6. The 034B-L uses a switch closure for wind speed measurement, and the 03002-L uses a low-level ac output for wind speed measurement. Both use a pulse channel on the data logger to measure wind speed.

  7. Most Campbell Scientific sensors are available as an –L, which indicates a user-specified cable length. If a sensor is listed as an –LX model (where “X” is some other character), that sensor’s cable has a user-specified length, but it terminates with a specific connector for a unique system:

    • An –LC model has a user-specified cable length for connection to an ET107, CS110, or retired Metdata1.
    • An –LQ model has a user-specified cable length for connection to a RAWS-P weather station.

    If a sensor does not have an –L or other –LX designation after the main model number, the sensor has a set cable length. The cable length is listed at the end of the Description field in the product’s Ordering information. For example, the 034B-ET model has a description of “Met One Wind Set for ET Station, 67 inch Cable.” Products with a set cable length terminate, as a default, with pigtails.

    If a cable terminates with a special connector for a unique system, the end of the model number designates which system. For example, the 034B-ET model designates the sensor as a 034B for an ET107 system.

    • –ET models terminate with the connector for an ET107 weather station.
    • –ETM models terminate with the connector for an ET107 weather station, but they also include a special system mounting, which is often convenient when purchasing a replacement part.
    • –QD models terminate with the connector for a RAWS-F Quick Deployment Station.
    • –PW models terminate with the connector for a PWENC or pre-wired system.
  8. Not every sensor has different cable termination options. The options available for a particular sensor can be checked by looking in two places in the Ordering information area of the sensor product page:

    • Model number
    • Cable Termination Options list

    If a sensor is offered in an –ET, –ETM, –LC, –LQ, or –QD version, that option’s availability is reflected in the sensor model number. For example, the 034B is offered as the 034B-ET, 034B-ETM, 034B-LC, 034B-LQ, and 034B-QD.

    All of the other cable termination options, if available, are listed on the Ordering information area of the sensor product page under “Cable Termination Options.” For example, the 034B-L Wind Set is offered with the –CWS, –PT, and –PW options, as shown in the Ordering information area of the 034B-L product page.

    Note: As newer products are added to our inventory, typically, we will list multiple cable termination options under a single sensor model rather than creating multiple model numbers. For example, the HC2S3-L has a –C cable termination option for connecting it to a CS110 instead of offering an HC2S3-LC model. 

Case Studies

Pennsylvania: University Weather Station
The Geography Department at Bucknell University has implemented a weather station to obtain meteorological data......read more

Privacy Policy Update

We've updated our privacy policy.  Learn More

Cookie Consent

Update your cookie preferences.  Update Cookie Preferences