Digital Adapters / SC-CPI
SC-CPI Datalogger-to-CPI Interface
Data Logger to CDM Bridge
Synchronized high-speed measurements
weather applications supported water applications supported energy applications supported gas flux and turbulence applications supported infrastructure applications supported soil applications supported

Overview

The SC-CPI is an interface between the serial port of later-model Campbell Scientific dataloggers (CR800/850, CR1000, and CR3000) and our new Campbell distributed modules (CDMs). The CDMs use the new CAN peripheral interface (CPI), and the SC-CPI allows the dataloggers listed above to connect to the CDM's CPI port. Future dataloggers will have CPI connections and will not need a bridge, but with the SC-CPI our current line of dataloggers will be able to take advantage of our CDM technology.

Benefits and Features

  • Enables a CR800, CR850 CR1000, or CR3000 to be part of a CPI/CDM network
  • Provides detailed CPI communication diagnostics
  • Supports monitoring of the serial or CPI load
  • Indicates if CPI frame errors occur
  • Provides information about each CPI module that it detects in its network

Images

SC-CPI shown with connector and 29526 cable attached (a Ships With item)
SC-CPI shown with connector and 29526 cable attached (a Ships With item)
SC-CPI shown with connector and 29526 cable attached (a Ships With item)

Specifications

Temperature Range
  • -25° to +50°C (standard)
  • -55° to +85°C (extended)
Current Drain 50 mA (active)
Dimensions 15.94 x 7.49 x 3.18 cm (6.28 x 2.95 x 1.25 in.) including ground lug
Weight 0.188 kg (0.415 lb)

Connectors

CPI RJ45
Serial Connect to Data Logger Screw terminal
Computer Configuration via Device Configuration Utility USB

Compatibility

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Dataloggers

Product Compatible Note
CR1000 (retired)
CR200X (retired)
CR216X (retired)
CR3000
CR800 (retired)
CR850 (retired)
CR9000X (retired)

Additional Compatibility Information

Data Logger Considerations

A 5-conductor cable connects the data logger to the SC-CPI, and an Ethernet cable connects the SC-CPI to the CDM.

The data logger operating system must be version OS 26.

Resources and Links



FAQs for

Number of FAQs related to SC-CPI: 2

  1. To communicate with CDM devices using the CPI protocol, the CR3000, CR1000, CR850, and CR800 dataloggers require an SC-CPI device. Only one SC-CPI device per data logger is required. It is expected that the design of future Campbell Scientific data logger products will work with CPI-based modules directly.

  2. The communications protocol used by CDM devices is the CAN Peripheral Interface (CPI), which includes methods that are proprietary to Campbell Scientific.

Privacy Policy Update

We've updated our privacy policy.  Learn More

Cookie Consent

Update your cookie preferences.  Update Cookie Preferences